0item(s)

You have no items in your shopping cart.

Prices are current as of Saturday, 25/05/2019.
Prices are GST exclusive. Tax is added at checkout.

Price On Request
Availability: Backorder
Product Code: S017

Please ensure the dropdown options are correct

If you are interested in this product, please contact us at sales@proscitech.com.

ProSciTech is proud to introduce the world's smallest ruler (5 micrometers) for the calibration of Transmission Electron Microscopes.
The MAG*I*CAL  has been developed to perform the three major calibrations of a TEM.

  • Image Magnification Calibration.
  • Camera Constant Calibration for Indexing Diffraction Patterns.
  • Image/Diffraction Pattern Rotation Calibration.


With this newly developed single crystal material, a single sample can replace up to 5 other calibration samples.
The sample consists of an ion milled cross section of a silicon single crystal.This consists of a series of atomically flat layers of Si and SiGe which have been grown epitaxially by MBE(molecular beam epitaxy). The thickness' and spacing of these layers are very accurately known and all other spacings on the sample are easily verified. The layer spacings are designed so that the sample can be used to calibrate the entire magnification range in a TEM-from 1000X to 1,000,000X. And, since the material is a single crystal, it can also be used to perform the camera constant calibration and the image diffraction pattern rotation calibration.
The sample comes with simple, specific instructions for all calibrations.

Figure 1. Diagram of the deluxe MAG*I*CAL calibration sample. The arrows indicate the four possible regions of interest on the sample where the calibration marks may be found. Note that this cross-sectional sample consist of two pieces of silicon wafer epoxied face-to-face, with additional silicon added as backing material to form a 3mm disk. To find the areas of interest at low magnification, look for the epoxy line on either side (between the arrows in the above figure).

Figure 2. TEM micrographs of the MAG*I*CAL calibration sample. The sample consists of a series of layers whose thickness are accurately known, based on the (111) lattice spacing of Si. Inset shows a higher magnification image of one of the layered structures.

Ultimate Calibration Standard for TEM, MAG*I*CAL™ 

Shipping

Orders with items in stock are packed within 24 hours. We ship with our best choice of courier, depending on goods ordered and shipping address provided.

Location

Standard delivery

Express delivery

Townsville/Local

Next day

N/A

Queensland

2-3 business days

N/A

NSW

4-10 business days

2-3 business days

SA/Tas/Vic/WA

6-14 business days

2-3 business days

Overseas

N/A

5-14 business days

*Note: Delivery times are as provided by our carriers and are estimates only. Delays may occur during peak periods, and due to factors outside the carriers' control.

Standard shipping is $15 in Australia (free on orders over $200). Add $5 to ship Express (under 2kg only)

Pickup

Order online and collect from our warehouse in Townsville.

Location

Freight Charge

Ready for collection

11 Carlton Street, Kirwan

$0

Once invoice has been emailed
(Less than 1 business day)



Just added to your wishlist:
My Wishlist
You've just added this product to the cart:
Go to cart page